AidaIDE 1.0.0-rc20 - Release Notes
This candidate brings together desktop and local browser improvements since rc19. There is no pricing or licensing change. Tools keep their existing permissions, licensing and device requirements.
AI Command Center
- The main AI toolbar button opens AI Command Center. The legacy AI sidebar is hidden by default; an explicitly saved visibility preference still applies.
- Message entry and run controls stay visible when the window is resized. Dense circuit diagrams scroll horizontally to keep labels and nodes readable.
- Circuit activity follows remaining work and clears when the run finishes, while failures keep their status.
Production and device deployment
- The new Production tab helps build, version, release and deploy your programs, with saved artifacts and deployment results.
- Python and Rust version discovery handles Windows line endings. Release creation retries brief Windows directory locks while retaining overwrite and failure checks.
- Linux server and droplet tools include SSH snapshots, reviewed release bundles, configured systemd logs and reviewed restarts.
- Deploy Lite requires explicit device permission and a current hardware check. Discovery and old device records do not grant installation permission.
- SSH public-key setup and key management are available for device connections.
Desktop workflows in the browser
The local web interface uses more of the desktop's shared stores and engines: database administration, project templates, cameras, interactive terminals, protocol tools, diagnostics, security scans, backup and recovery, training, model workflows, settings and Extension Studio.
IC and SoC authoring includes shared catalogs, graph transactions, private clipboard and history, saved workspaces, reviewed layout and debugger controls. Long-running browser operations track their owning session, worker results and cleanup.
Fleet, mapping and remote access
- Fleet Map includes terrain and line-of-sight tools, RF coverage and address serviceability, mast heights, canopy data and offline map areas. Fleet cards and device panes have layout and rendering improvements.
- The terminal supports richer colors, full-screen programs and keyboard input.
- PC-side Cloud Portal changes follow the actual web-server port, preserve browser origin and isolate PC sessions, with improved tunnel recovery and remote-viewer disconnect handling.
- Portal server deployment and the companion Android release remain separate.
Authoring and startup
- AidaHL authoring includes named functions and a portable starter. Builder practice, saved designs and the Detailer workflow have been expanded.
- Workbench starts with a traditional arrangement and supports saved native workspaces and optional panels.
- Startup defers more imports and background work. GPIO diagrams load their shared constants before the renderer, fixing a circular import found during packaging.
- The web server honors
AIDAIDE_WEB_PORTeven when it differs from the saved desktop setting. - Browser changes simplify phone navigation, unify older tool pages and preserve live connected Wi-Fi PC survey maps.
What's new in rc20
- Set Up SSH Server. The File, Network and Security menus and Settings gain Set Up SSH Server…. On Windows it installs and starts OpenSSH Server, replaces the broad default firewall rule with an "AidaIDE SSH (private network)" rule, can create a local account, authorize a public key and test a login, and Disable stops the server and turns its firewall rules off while keeping files and accounts. On macOS and Linux it shows setup instructions.
- Linux self-update. Installed Linux copies show the startup update prompt (Skip Once is available). Update Now unpacks the new tarball, runs its
install.shand relaunches. - Cloud sign-in. If the browser opens but does nothing (for example snap Chromium), the sign-in is no longer stranded.
- Spectrum tab. Clicking a site header or a device row no longer raises an error.
- Settings sync. Sync archives leave out nested passwords without blocking older backups.
Wi-Fi site maps, switch controls and UniFi consoles
Added after the October 22 candidate; included in the published rc20 artifacts.
- Wi-Fi site maps. The Wi-Fi surveys window gains a Site maps tab. Walks recorded on the phone (this needs a newer AidaIDE Android build that isn't published yet; today's Android download is 0.59.1) are received per site, kept as reusable maps, and compared visit to visit on one aligned grid. Building outlines, map alignments and named access points drawn on the phone are kept on the PC: the outline is drawn as the view boundary with unmeasured space hatched, and readings can be shown as Inside outline, Outside readings or Whole map. Signal model, Measured and AP estimates layers are computed on the PC from the map's own readings with the same arithmetic the phone uses. An empty map or comparison says which kind of empty it is.
- Survey uploads are checked before anything is filed. A retry is a no-op; a changed, duplicate, self-linked, cross-kind or forked annotation revision is refused; a failed or interrupted finish never loses an accepted visit; a deletion that cannot establish its set-aside copies deletes nothing. Desktop builds now require the phone survey receiver and site map modules.
- Switch port controls (MikroTik RouterOS). On MikroTik RouterOS switches, Switch Monitor port details offer Disable / Enable, a comment and a rename beside PoE. Each action is planned first (refusals and blockers stated before confirmation), shown as the command it will send, sent once, audited, and the switch is read again. The phone's port actions go through the same route: writes can be unlocked (typed UNLOCK) and locked per switch, a PoE-less switch's answer or an invalid value counts as a refusal rather than a silent success, and port names that cannot be quoted are refused. Spaced port names are offered underscored renames.
- Uplink guard before a cut. Before any write that would cut a port, the switch is asked over the same SSH session which ports carry the default gateway (route, ARP, bridge-learned MAC, bond members) and the SSH session itself. Those ports are refused, and when the switch cannot say, nothing that cuts a port is sent.
- UniFi OS consoles, read-only. In the Router and Firewall tabs of a device's page in the PC's local web interface (in a browser or the phone app, after you sign in), AidaIDE reads a UniFi OS console (UDM, UDM Pro and SE, UDR, Cloud Gateways) through its local Network API: WANs and failover state, routes, addresses and VLANs, ports, leases and fixed IPs, zone-based firewall policies or the older rules, port forwards, and the switches and access points it manages. The console sign-in uses a local admin. The console's certificate is remembered on first sight and a changed one refused. Every call after sign-in is a read.
- Saved device passwords survive adapter changes. Saved credentials encrypted under a previous local network adapter's key are recovered by trying this computer's adapters, including saved connections in Connection Manager. Unreadable ones are reported once and kept as they are, never replaced with an empty password.
What was checked
Targeted acceptance covered the installed Windows executable and the Linux archive on Ubuntu 24.04 under WSL2: installation and upgrade, database drivers, installed workers, retained Linux settings, native UI flows and authenticated browser pages. Linux GUI tests ran under Xvfb.
Follow-up checks passed for OTA update and rollback against disposable SSH targets, Fleet registration and staged rollout, Portal sessions, licensing and AI handling. The installed Linux AI client also completed small live requests through the configured Anthropic and Google providers.
These checks do not certify every feature, physical hardware, ARM or Jetson hosts, live paid Fleet actions, Cloud Portal reconnection, or every AI workflow. Windows remains the primary supported path; Linux remains experimental. No macOS artifact is included.
Artifact integrity
These are the published rc20 artifacts, as served by the update feed (/latest.json).
Windows installer
AidaIDE_Setup_1.0.0-rc20.exe
148,229,369 bytes
SHA-256: 0f22c283f9b2693700a491e5d5c1ffef246f53b718634ddbb4d0ba2628f42310
Linux experimental source archive
AidaIDE-1.0.0-rc20-linux.tar.gz
23,803,506 bytes
SHA-256: 1c5d920dbb0e5978dd935835e38c4ff70b99ae716e61fa5988cabf64e2f46209
The companion Android app has its own version and repository. It is not a desktop host download.
rc20 is available through your free account. Installed copies update over the air.
Create a free account